Settings guide

Tubolito SYNCD Settings

Reference for TubeWitch for Tubolito SYNCD settings in Garmin Connect IQ order. Start with units, sensor names and pressure targets, then confirm live pressures before tuning the display and alerts.

Tubolito SYNCD box and orange inner tube
Tubolito SYNCD Bluetooth LE
ACTIVE SENSOR SET
  • Active Sensor Set Choose which Sensor Set is shown in the Data Field. Manually select the active set or use Auto Switch to scan each configured set for 10 seconds. If you only have one set, Auto is not recommended.
SENSOR SET #1-5
  • Sensor Set Name Optional. Name the bike or wheelset. The name is also shown in Connect IQ stats.
  • Enabled Sensors Choose Front & Rear, Front Only or Rear Only.
  • Front Sensor ID and Rear Sensor ID Enter the full sensor ID, such as SYNCD-C3D0. The SYNCD prefix and hyphen must be included. Place the ID in the slot for the correct wheel.
  • Front Low Target / Front High Target Set the low and high pressure limits for the front wheel.
  • Rear Low Target / Rear High Target Set the low and high pressure limits for the rear wheel.

Targets use the selected PSI, bar or kPa unit. A target of 0 is unset and disables that individual comparison. All targets start at 0.

When both targets are set, the high target must be greater than the low target. If it is not, TubeWitch ignores the conflicting high target and keeps the low comparison.

UNIT OF MEASURE
  • Unit of Measure PSI, kPa, or BAR. Garmin reboot recommended after the unit change.
  • Decimal Places Number of digits to the right of the decimal. Forcing extra digits may cause labels to be truncated on small data fields.
  • Show Unit of Measure Show or hide the unit label in the data field.

Extra precision can make small layouts harder to scan. Limit precision to what remains readable while moving. Auto is recommended.

After changing units, update pressure targets in every sensor set. Saved target numbers are not automatically converted; they are interpreted in the newly selected unit.

SENSOR LABELS
  • Show Front/Rear Labels Show or hide front and rear labels in the data field.
  • Show Sensor IDs Show the final four characters of valid full sensor names, such as C3D0, in the data field.
  • Show Sensor Set Name Show the sensor set name in the data field. It may be truncated on small data fields.
  • Horizontal Layout Label Delimiter Choose the separator used on horizontal layouts.

Useful during setup and multi-bike use, but these can crowd very small layouts.

DISPLAY
  • Display Style TubeWitch Mode is the default, but it may be unavailable on some devices that are not yet fully supported. Compatibility Mode uses dynamic font sizing and positioning and works on all devices.
  • Layout Orientation Auto, Vertical, or Horizontal. Horizontal Orientation is not available in narrow fields while using TubeWitch Display Mode.
  • Background Color Auto, Light, or Dark.

TubeWitch Mode is default. Compatibility Mode uses dynamic sizing and positioning for broader device coverage.

Auto, Vertical, or Horizontal layout behavior.

Auto, Light, or Dark styling depending on layout and page contrast.

TOUCH SETTINGS
  • Touch Data Field Enables Touch to Switch Sensor Sets, Touch to Disable TubeWitch, Touch to Rescan after timeout and Touch to Stop Alarm Repeats. Only available on touchscreen devices.
SENSOR TIMEOUT
  • Sensor Timeout Default 15 Minutes. During an activity, TubeWitch times out if no sensors are found. No timeout is applied if an activity is not started.
AUTO SWITCH SCAN DELAY
  • Auto Switch Scan Delay Default 60 seconds. If all enabled sensors become stale after 250 seconds (4 minutes, 10 seconds) without valid pressure updates while Active Sensor Set is Auto Switch, TubeWitch then waits for this delay before scanning other sets again at 10 seconds each.
HIGH / LOW PRESSURE ALARMS

(Set pressure targets in each Sensor Set in TubeWitch Settings)

TubeWitch calculates low and high status alerts from the received pressure and your configured limits.

Default target values of 0 do not enable pressure-limit alarms.

  • Audible Alert Enable or disable audible pressure alerts on supported Edge Devices and watches.
  • Pop Up Alert Enable popup alerts on newer supported devices.
  • Vibration Alert Enable vibration alerts on supported watches.
  • Alarm Delay Set how many seconds a tire must be high or low before triggering an alarm.
  • Reset Delay Set how many seconds a tire must be within target before resetting the pressure alarm.
  • Alarm Repeat Set the number of additional repeats after the first alarm (90 seconds apart). A value of 0 adds no repeats.
  • Audible Alarm Tone Select the sound used for audible alerts.
  • Data Field Alarm Box Color Choose the box color used for the pressure alarm state. The color change is always active and instantaneous while the condition exists.
ACTIVITY RECORDING

(Garmin reboot required after making recording changes)

  • Record Front Pressure Record front pressure into the activity.
  • Record Rear Pressure Record rear pressure into the activity.
  • Record Front Pressure Alarm Record front pressure alarm status.
  • Record Rear Pressure Alarm Record rear pressure alarm status.
  • Record Front Pressure Stale Data Indicator Record front stale data indicator status.
  • Record Rear Pressure Stale Data Indicator Record rear stale data indicator status.
  • Record Sensor Set # Record the sensor set number used in the activity.

For post-ride review, the most useful additions are often set number and alarm status alongside raw pressure.

Need more help?

If your setup or settings issues are not addressed on this page, see Troubleshooting for step-by-step fixes or FAQ for common Tubolito setup and use questions.